Common array manager.

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

Common array manager. Things To Know About Common array manager.

The SAS expander on the Multi-Fabric NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which …Jun 20, 2019 · Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.Support data for an array is collected and saved in the Common Array Manager by selecting array > General Configuration > Support Data. On the Windows 2008 server, disable “Do not save encrypted pages to disk.” Go to Tools > Internet Options > Advanced > Security and uncheck "Do not save encrypted pages to disk." Linux platformsSun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage 2530-M2 Array - Version Not Applicable and later Information in this document applies to any platform. Goal. Sun Storage 2500, 2500-M2, and 6000 arrays support Dynamic Volume Expansion (DVE). DVE is an operation that allows the user-visible …

vi Sun StorageTek Common Array Manager ユーザーズガイドオープンシステム用• 2010 年 2 月 FMS エージェントの構成 65 アレイの健全性の監視の有効化 67 アラームとイベントの監視 67 アラーム情報の表示 68 アラームの管理 70 アラームの承認 70 1 つまたは複数のアラーム ...

From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ...

The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. The purpose of this document is to help troubleshoot the Sun Storage Common Array Manager (CAM) login problem that produces the error: 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.

The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.

Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer.

Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux ForumsCommon Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a …(Doc ID 1012806.1) Last updated on MARCH 24, 2021. Applies to: . Sun Storage Common Array Manager (CAM) - Version 5.0 and later. All Platforms. Goal. … “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application.

This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of … Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... 使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... Feb 21, 2023 · This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component ... Sun Storage Common Array Manager (CAM) - Version 5.0 to 5.1 [Release 5.0] Oracle Solaris on SPARC (64-bit) Oracle Solaris on SPARC (32-bit) Oracle Solaris on x86-64 (64-bit) Oracle Solaris on x86 (32-bit) Symptoms. Execution of the RunMe.bin installer, or RunMe.bin -c, on Solaris[TM] Operating System, fails with:This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of …It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).

Jun 20, 2019 · Purpose. Sun Storage Common Array Manager (CAM) is used for managing and monitoring many Sun Storage arrays. CAM's notification capabilities include on-screen alarms and events via the BUI, and CAM can also send notifications via email or SNMP. This document covers setting up SNMP notifications from CAM. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of …

“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, …Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun …Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsCommon Array Manager. user-lvozg Feb 12 2023. Unable to see StorageTek6410 in Oracle Java Web Console after installing Common Array Manager, but I can only see Hosts statistics such as cpu usage, local hard drive and memory usage status.Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.The Sun StorageTek [TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge [TM], Sun StorageTek [TM], StorageTek …iv Sun StorageTek Common Array Manager CLI Guide • April 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 29 Examples 30

See your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.

Storage Common Array Manager 6.10 Update. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 …

Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forThis guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forLearn how to use the command line interface (CLI) to manage your Sun StorageTek Common Array Manager (CAM) arrays. This quick reference guide provides the syntax and examples of the most common CLI commands. 通过打开浏览器并输入下列地址,从主阵列管理服务器登录 Sun Storage Common Array Manager: https://host-name:6789. 其中,host-name 为连接到该阵列的服务器的 DNS 名称。. 在“存储系统摘要”页面中,单击“注册”并按照向导中的说明将该阵列注册到第一个服务器的 IP 地址 ... Common controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays … The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Sun Storage Common Array Manager (CAM) - Version 6.10 to 6.10 [Release 6.0] Information in this document applies to any platform. Purpose. The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.10. Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ... Sun Storage Common Array Manager Software 6.7.0 Release Notes: PDF: Sun Storage Array Baseline Firmware: PDF: Sun Storage Common Array Manager Array Administration Guide, Version 6.7.0: PDF: Sun Storage Common Array Manager Quick Start Guide: PDF: Sun Storage Common Array Manager Installation and Setup Guide: …

The SAS expander on the Multi-Fabric NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which …Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.10 [Release 6.0] Information in this document applies to any platform. Symptoms. When attempting to launch Service Advisor from Sun Storage Common Array Manager (CAM), the following message appears: "Service advisor package not installed for this type of device."9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Instagram:https://instagram. barksdale fcuwatch the gangster the cop the devileasy word searchwe transfer Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look … tokyo to vegas flight timebrinks armored Sun StorageTek Common Array Manager Release Notes, part number 820-5749-12. Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes … dotloop sign 通过打开浏览器并输入下列地址,从主阵列管理服务器登录 Sun Storage Common Array Manager: https://host-name:6789. 其中,host-name 为连接到该阵列的服务器的 DNS 名称。. 在“存储系统摘要”页面中,单击“注册”并按照向导中的说明将该阵列注册到第一个服务器的 IP 地址 ... The "Services" application can be launched in Windows to confirm that the service name "Sun_STK_FMS" (Sun Storage Common Array Manager Fault Management Service) is not running. See the example below: Additionally, the following errors may exist in the file C:\Program Files (x86)\Sun\Common Array …From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.